Search results for "Bone Cements"
showing 10 items of 12 documents
Autologous Iliac Bone Graft Compared with Biphasic Hydroxyapatite and Calcium Sulfate Cement for the Treatment of Bone Defects in Tibial Plateau Frac…
2019
Background Bone-graft substitutes are commonly used for the augmentation of traumatic bone defects in tibial plateau fractures. However, their clinical performance compared with that of autologous bone-grafting, the gold standard in bone defect reconstruction, still remains under debate. This study investigates the differences in quality of life, pain, and radiographic outcomes in the treatment of tibial plateau fracture-associated bone defects with either autologous bone grafts or a bioresorbable hydroxyapatite and calcium sulfate cement (CERAMENT BONE VOID FILLER [CBVF]; BONESUPPORT). Methods In this study, 135 patients with acute depression and split-depression fractures of the proximal …
Crystallized nano-sized alpha-tricalcium phosphate from amorphous calcium phosphate: microstructure, cementation and cell response
2015
New insight on the conversion of amorphous calcium phosphate (ACP) to nano-sized alpha tricalcium phosphate (α-TCP) provides a faster pathway to calcium phosphate bone cements. In this work, synthesized ACP powders were treated with either water or ethanol, dried, crystallized between 700 and 800 °C, and then cooled at different cooling rates. Particle size was measured in a scanning electron microscope, but crystallite size calculated by Rietveld analysis. Phase composition and bonding in the crystallized powder was assessed by x-ray diffraction and Fourier-transform infrared spectroscopy. Results showed that 50 nm sized α-TCP formed after crystallization of lyophilized powders. Water trea…
Does Optimal Volume Fraction in Percutaneous Vertebroplasty Prevent Cement Leakage?
2018
EMG-guided percutaneous placement of cement-augmented pedicle screws for osteoporotic thoracolumbar burst fractures
2017
Background: Percutaneous techniques have increasingly gained popularity in recent years. The application of technological innovation, including neuromonitoring techniques, has the potential to increase the safety and efficacy of these procedures. Methods: Thirty patients suffering from osteoporotic dorsolumbar burst fracture were prospectively enrolled in this study. The patients underwent percutaneous fenestrated pedicle screw fixation augmented with polymethylmethacrylate (PMMA) injection. A novel surgeon-dedicated neuromonitoring device was used in order to increase the safety and the accuracy of the screw insertion. A second group of 30 patients who did not undergo neuromonitoring durin…
Modes of periacetabular load transfer to cortical and cancellous bone after cemented versus uncemented total hip arthroplasty: A prospective study us…
2008
Stress-shielding and periprosthetic bone loss after total hip arthroplasty (THA) may be clinically relevant for high-demand patients. Analysis of cortical and cancellous bone density (BD) changes in vivo after THA is of interest to basic science researchers and joint reconstruction surgeons. An insufficient periprosthetic bone stock may predispose to migration, early mechanical failure, and major problems in revision surgery. We used computed tomography (CT)-assisted osteodensitometry in two prospectively analyzed cohorts after cemented (n = 21) versus noncemented (n = 23) cup fixation. Periacetabular BD (mgCaHa/mL) was determined in five CT scans cranial and five CT scans at the level of t…
Pathogenesis of circulatory reactions triggered by nervous reflexes during the implantation of bone cements.
1983
Circulatory and respiratory reactions during the implantation of joint endoprostheses have been observed for years. The components of the bone cements used for anchoring (methyl methacrylate monomer) or the outpour of bone marrow substances from the affected bone marrow cavity are thought to be chiefly responsible for these effects. However, our previous investigations demonstrated unambiguously that reactions of this type can be attributed to direct nervous-reflex mechanisms triggered by the pressure rise in the medullary canal, and that, in addition, bone marrow embolism plays a part in serious circulatory incidents. The investigations on which the present paper is based have confirmed th…
[Percutaneous vertebroplasty]
2003
Methotrexate-Loaded Polymethylmethacrylate Bone Cement for Local Bone Metastasis Therapy: Pilot Animal Study in the Rabbit Patellar Groove
2008
Local chemotherapy is an option in bone metastasis treatment. On the other hand, evaluation of side effects on bone is a difficult issue in drug development and biomaterials research. Most animal models to date are inappropriate or not feasible. Rabbits are an alternative to other bigger mammals and have an appropriate bone structure compared to rats and mice. The patellar groove model of the rabbit offers a standardized and sensitive model to evaluate bone-compromising drug effects. We tested the system with a reproducible polymethacrylate implant as carrier and loaded this system with methotrexate. Three methotrexate concentrations were used in the test samples (250 mg, 1 g and 4 g per 40…
A ten-year follow-up of the Reflection cementless acetabular component.
2008
We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…
Reaction of the bone structure to methotrexate-Palacos flow y. Experimental investigations in animals.
1989
With the combined osteosynthesis of pathological fractures in association with tumors and/or metastases in mind, E. Merck (Darmstadt, FRG) developed a bone cement containing a cytostatic agent, methotrexate-Palacos flow y (MTX-Pf). The animal-experimental study presented here investigates the tolerability of MTX-Pf in the femurs of rabbits with lateral comparison. In these investigations we used both the concentration of 0.63% MTX, as is currently used in standard clinical surgery, as well as a much higher concentration of 2.5% MTX. The histological sections were investigated using microradiographic methods and provided no indication of any significant differences between the femora with th…